AC input voltage range 90-290VAC
Protections against:short circuit/over current/over volage/over temperature
Power Factor≥0.9
Meets IEEE 802.3af/at/bt atandard
Support 10Mbps/100Mbps/1G/2.5G/5G/10G Ethernet transmission
Input Voltage | 90-290VAC | Operationg Temperature | -40~65℃ | ||||||||
Input Current | 1.8A | Storage Temperature | -40~70℃ | ||||||||
Efficiency | | 85% | | ||||||||
Output Voltage tolerance | ±3% | Humidity | 5% to 95% ,non-condensing | ||||||||
Power Factor | 0.9 | MTBF | 100000 hours at full load at 25℃ambient,calculated per MIL-HKBK-217 | ||||||||
Safety Standard | IRAM(IEC62368-1),RCM(AS/NZS62368.1),NOM(NOM-001-SCFI-1993),PSB(IEC60950-1). GS(EV62368-1),PSE(J62368-1),FCC(Part15),BIS(IEC60950-1),BSMI(CNS14336-1),EAC(IEC62368-1),CE(EN62368),CCC(GB4943.1),cULus(UL62368-1), CB(IEC62368-1) | ||||||||||
Weight | 570g | Dimensions | 191.5mm (w/o hanging ring) /222mm(L) ;80mm (W) ; 40mm (H) | ||||||||
Applications | IP Phone Wireless AP, POS device,etc. |
Output data
Model | Voltage (V) | Current (A) | Ripple (mV) | Av.Eff. (%)Min |
POE90-560161 | 56.0 | 0.09-1.61 | 200 | 85.0 |