Product Features | |||||
Medical safety approvals | |||||
2 MOPP input to output isolation | |||||
Energy efficiency Level VI | |||||
Touch current ≤ 100μA | |||||
≤0.21W standby power | |||||
Peak load:200% rated load @ 230Vac | |||||
Up to 5000m operating altitude | |||||
Adjustable resistance to adjust output voltage | |||||
Windess design featrues,natural air cooling |
Input |
Input Voltage Range:90-264VAC(90-115VAC refer to derating curve)
Frequency Range:47-63Hz
Input Current:2.0A max at 100VAC
Inrush Current:120A max at 240VAC cold start
Touch Leakage Current(max):≤ 100μA at 264VAC
Environmental
Operating Temperature: -30℃ to 70℃(45℃ to 70℃ refer to derating curve)
Storage Temperature:- 40℃ to 80℃
Operating Humidity:5 to 90% RH,non-condensing
Storage Humidity::5 to 95% RH
Operating Altitude:5,000 M
General
Dimensions:101.6(L)×50.8(W)×32.0(H)mm
Weight:180g
MTBF:>200000hrs MIL-HKBK-217 at 25℃
ANSI/AAMI ES60601-1
Safety Approvals
Safety Agency/Mark
Medical
I.T.E.
CB IEC60601-1 - TUV-SUD Mark
EN60601-1
- NRTL
-
Model Number | Voltage (V) | Current (A) | Rated Power (W) | Ripple & Noise (max) mVpk-pk | Voltage Tolerance | Line & Load Regulation | Efficiency | Start Up delay |
UES150-XXXYYYSPA-OP | 12.00 | 0.01-11.00 | 132 | 100 | ±5% | | 92% | ≤3s |
15.00 | 0.01-9.00 | 132 | 100 | Line: ±1% | 92% | ≤3s | ||
18.00 | 0.01-8.00 | 144 | 120 | | 93% | ≤3s | ||
24.00 | 0.01-6.00 | 144 | 120 | Load: ±5% | 93% | ≤3s | ||
36.00 | 0.01-4.00 | 144 | 120 | | 94% | ≤3s | ||
48.00 | 0.01-3.12 | 150 | 120 | | 94% | ≤3s |