Product Features
Medical & I.T.E. safety approvals |
2 MOPP input to output isolation |
Touch current≤100μA |
≤0.15W standby power |
12V to 24V outputs,up to 60W |
Up to 5000m operating altitude |
Interchargeable AC plugs |
Input |
Input Voltage Range:80-264VAC
Frequency Range:47-63Hz
Input Current:1.7A,at 80VAC
Touch Leakage Current(max):≤ 100μA at 264VAC
Environmental
Operating Temperature: 0℃ to 40℃
Storage Temperature:- 5℃ to 60℃
Operating Humidity:10 to 90% RH,non-condensing
Storage Humidity::5 to 90% RH
Operating Altitude:5,000 M
General
Dimensions:90.5(L)×33.5(W)×58.8(H)mm
Weight:220g
MTBF:>100000hrs MIL-HKBK-217 at 25℃
Safety Approvals | |||||||||||
Safety Agency/Mark | Medical | I.T.E.(Meets) | |||||||||
CB | IEC60601-1/60601-1-11 | IEC62368-1 | |||||||||
UL | ANSI / AAMI ES60601-1/60601-1-11 | UL62368 | |||||||||
CAN / CSA-C22.2 NO。60601-1 | |||||||||||
TuV SUD/Mark | EN60601-1/EN60601-1-11 | - | |||||||||
TuV SUD/ GS | - | EN62368-1 | |||||||||
CE | - | EN62368-1 | |||||||||
CCC | | | | - | | | | GB4943.1 | | | |
FCC | | | | - | | | | FCC PART 15 | | | |
Model Number | Voltage (V) | Current (A) | Rated Power (W) | Ripple & Noise (max) mVpk-pk | Voltage tolerance | Line& Load Regulation | Efficiency (Average) | Start Up delay |
UES60LCP2-XXXYYYSPA | 12.0 | 0.01-5.00 | 60.0W | 200 | ±5% | Line: ±1% Load: ±5% | 89.00% | ≤3s |
12.1-13.0 | 0.01-4.60 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
13.1-14.0 | 0.01-4.28 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
14.1-15.0 | 0.01-4.00 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
19.0 | 0.01-3.15 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
19.1-20.0 | 0.01-3.00 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
20.1-21.0 | 0.01-2.85 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
21.1-22.0 | 0.01-2.72 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
22.1-23.0 | 0.01-2.60 | 60.0W | 200 | ±5% | 89.00% | ≤3s | ||
23.1-24.0 | 0.01-2.50 | 60.0W | 200 | ±5% | 89.00% | ≤3s |