Product Features
Medical & I.T.E. safety |
≤0.8W standby power |
inputs voltage(11.5-16Vdc) |
19V-24V outputs,up to 120W |
Input |
Input Voltage Range:11.5-16Vdc
Input Current:18A MAX
Inrush Current:25A max at 11.5Vdc cold start
Environmental
Operating Temperature: -10℃ to 40℃
Storage Temperature:- 20℃ to 80℃
Operating Humidity:10 to 95% RH,non-condensing
Storage Humidity::10 to 95% RH
General
Dimensions:137.0(L)×63.0(W)×33.0(H)mm
Weight:About 480g
MTBF:>200000hrs MIL-HKBK-217 at 25℃
Safety Approvals | |||||||
Safety Agency/Mark | Medical(Meet) | I.T.E(Meet) | |||||
CB | IEC60601-1 | IEC62368-1 | | ||||
UL | | ANSI/AAMI ES60601-1 CAN/CSA-C22.2 NO.60601-1 | UL62368 | | |||
TuV-Mark | | EN60601-1 | EN62368-1 | |
Model Number | Voltage (V) | Current (A) | Rated Power (W) | Ripple & Noise (max) mVpk-pk | Voltage tolerance | Line& Load Regulation | Efficiency (Average) | Start Up delay |
UED120-XXXYYYSPA | 19.0 | 0.01-6.32 | 120 | 200 | ±5% | Line: ±1% Load: ±5% | 89% | ≤3.5s |
19.1-20.0 | 0.01-6.00 | 120 | 240 | ±5% | 89% | ≤3.5s | ||
20.1-21.0 | 0.01-5.71 | 120 | 240 | ±5% | 89% | ≤3.5s | ||
21.1-22.0 | 0.01-5.45 | 120 | 240 | ±5% | 89% | ≤3.5s | ||
22.1-23.0 | 0.01-5.21 | 120 | 240 | ±5% | 89% | ≤3.5s | ||
23.1-24.0 | 0.01-5.00 | 120 | 240 | ±5% | 89% | ≤3.5s |