Product Features | ||||
Meet medica l& I.T.E. safety approvals | ||||
Energy efficiency Level VI | ||||
Touch current ≤ 100μA | ||||
≤0.1W standby power | ||||
5.0V-20.0V outputs,up to 30W | ||||
Up to 5000m operating altitude | ||||
Support PD3.0,PPS,QC4.0,FCP,SCP fast charging protocol |
Input |
Input Voltage Range:90-264VAC
Frequency Range:47-63Hz
Input Current:0.7A at 90VAC
Inrush Current:80A max at 240VAC cold start
Touch Leakage Current(max):≤ 100μA at 264VAC
Environmental
Operating Temperature: 0℃ to 40℃
Storage Temperature:- 20℃ to 80℃
Operating Humidity:10 to 90% RH,non-condensing
Storage Humidity::5 to 95% RH
Operating Altitude:5,000 M
General
Dimensions:80(L)×30(W)×57.9(H)mm
Weight:100g
MTBF:>100000hrs MIL-HKBK-217 at 25℃
Safety Approvals | |||||||||||
Safety Agency/Mark | Medical(Meet) | ITE(Meet) | |||||||||
CB | IEC60601-1 | IEC62368-1 | |||||||||
UL | ANSI / AAMI ES60601-1 CAN / CSA-C22.2 NO.60601-1 | UL62368-1 CAN / CSA-C22.2 NO.62368-1 | |||||||||
TuV SUD/Mark | | | | EN60601-1 | | - | | | | ||
TuV SUD/GS | | | | - | | EN62368-1 | | | | ||
CE | - | EN62368-1 | |||||||||
CCC | | | | | | GB4943.1 | | | |||
FCC | | | | | | FCC PART 15 | | | |||
| | | | | | | | |
Model Number | Voltage (V) | Current (A) | Rated Power (W) | Ripple & Noise (max) mVpk-pk | Voltage tolerance | Line& Load Regulation | Efficiency (Average) | Start Up Delay |
UES30LCP1-SPC | 5.0 | 0.01-3.00 | 15.00 | 400 | ±5% | Line: ±2% Load: ±5% | 81.38% | ≤3s |
9.0 | 0.01-3.00 | 27.00 | 400 | ±5% | 86.62% | ≤3s | ||
12.0 | 0.01-2.50 | 30.00 | 400 | ±5% | 86.95% | ≤3s | ||
15.0 | 0.01-2.00 | 30.00 | 400 | ±5% | 86.95% | ≤3s | ||
20.0 | 0.01-1.50 | 30.00 | 400 | ±5% | 86.95% | ≤3s |