Product Features
Medical & I.T.E. safety approvals |
2 MOPP input to output isolation |
Touch current≤100μA |
Energy efficiency level VI |
≤0.1W standby power |
5V /9V/12V /15V/20V outputs,up to 33W |
Up to 5000m operating altitude |
Optional fixed plug/interchangeable plug design |
Meet USB PD3.0&QC3.0&QC2.0 fast charge agreement |
Input |
Input Voltage Range:80-264VAC
Frequency Range:47-63Hz
Input Current:0.9A,at 80VAC
Touch Leakage Current(max):≤ 100μA at 264VAC
Environmental
Operating Temperature: 0℃ to 40℃
Storage Temperature:- 40℃ to 80℃
Operating Humidity:10 to 90% RH,non-condensing
Storage Humidity::5 to 90% RH
Operating Altitude:5,000 M
General
Dimensions:90.5(L)×33.5(W)×48.0(H)mm
Weight:160g
MTBF:>60000hrs MIL-HKBK-217 at 25℃
Safety Approvals | |||||||||||
Safety Agency/Mark | Medical | I.T.E.(Meets) | |||||||||
CB | IEC60601-1/60601-1-11 | IEC62368-1 | |||||||||
UL | ANSI / AAMI ES60601-1/60601-1-11 | - | |||||||||
CAN / CSA-C22.2 NO。60601-1 | |||||||||||
TuV SUD/Mark | EN60601-1/EN60601-1-11 | | |||||||||
TuV SUD/ GS | - | EN62368-1 | |||||||||
CCC | | | | - | | | | GB4943.1 | | | |
PSE | | | | - | | | | J62368-1 | | | |
RCM | | | | - | | | | AS/NZS62368.1 | | | |
CE | - | EN62368-1 | |||||||||
FCC | | | | - | | | | FCC PART 15 | |||
BSMI | | | | - | | | | CNS 14336-1 | |||
NOM | | | | - | | | | NOM-001-SCFI-2018 |
Rated Power (W) Voltage tolerance Line& Load Regulation Efficiency (Average) Start Up delay Line: ±1% Load: ±5%
Model Number
Voltage
(V)
Current
(A)
Ripple & Noise
(max)
mVpk-pk
UES33LZ-SPC
5.0 0.01-3.00 15.00 200 ±5%
81.39% ≤3s
9.0 0.01-3.00 27.00 200 ±5%
86.62% ≤3s
12.0 0.01-2.50 30.00 200 ±5%
86.95% ≤3s
15.0
0.01-2.20 33.00 200 ±5%
87.20% 20.0 0.01-1.65 33.00 200 ±5%
87.20%